4040 RO Membrane

Model

BW30-4040

Others Specifications

  • Efficiency

    • Permeate Flow: gpd (m³/d) 2400 (9.1)
    • Salt Rejection: % 98 – 99
  • Type

    • Configuration : Polyamide Thin Film Composite
    • FRP : Epoxy – Vinylester
    • Active Area: ft² (m²) 81 (7.5)
  • Application Data

    • Applied Pressure : psig (bar) 225 (15.5)
    • Maximum Operating Temperature : °F(°C) 113 (45)
    • Maximum Feed Flow Rate: gpm(m³/h) 16 (3.6)
    • Maximum Pressure Drop : psig(bar) 15 (1.0)
    • pH Range, Continuous (Cleaning) : 2-11 (1-12)
    • Maximum Feed Silt Density Index : SDI < 5
    • Maximum Chlorine Concentration: < 0.1 ppm

Product Description

Hi-Tech BW30-4040 RO membrane elements are made by the most advanced technique polyamide RO membrane sheets and combined with experience in the process of rolling membranes for years. Performance is excellent and stable exceptionally. Covering a complete range from 50GPD to 400GPD. Application Data Applied Pressure : psig (bar)225 (15.5)225 (15.5)225 (15.5)

Hi-Tech Membrane BW30 – 4040Hi-Tech Membrane CP - 4040Hi-Tech Membrane CP – 4040Hi-Tech Membrane ES - 4040Hi-Tech Membrane ES – 4040
ModelHi-Tech Membrane BW30 – 4040Hi-Tech Membrane CP – 4040Hi-Tech Membrane ES – 4040
Photohi-tech-membrane-cp-4040-smallHi-Tech Membrane ES - 4040
EfficiencyPermeate Flow: gpd (m³/d)2400 (9.1)2400 (9.1)2650 (10.0)
Salt Rejection: %98 – 9998 – 9998 – 99
TypeConfigurationSpiral WoundSpiral WoundSpiral Wound
FRPEpoxy – VinylesterEpoxy – VinylesterEpoxy – Vinylester
Active Area: ft² (m²)85 (7.9)85 (7.9)80 (7.5)
Maximum Operating Temperature : °F(°C)113 (45)113 (45)113 (45)
Maximum Feed Flow Rate: gpm(m³/h)16 (3.6)16 (3.6)16 (3.6)
Maximum Pressure Drop : psig(bar)15 (1.0)15 (1.0)10
pH Range, Continuous (Cleaning)2-11 (1-12)2-11 (1-12)2-10 (1-12)
Maximum Feed Silt Density IndexSDI < 5SDI < 5SDI < 5
Maximum Chlorine Concentration< 0.1 ppm< 0.1 ppm< 0.1 ppm

BW30-4040 RO Membrane Features:

  • Uses the most advanced membrane film technology and manufacturing processes
  • Provides high rejection stability even with high TDS manufactured in our ISO 9001:2008 Certified Facilities,
  • Less fouling, Less frequency cleaning and More consistent
  • 100% Performance and Quality Tested
  • Backed by our Experienced Technical Support Staff
  • High Quality for Consistent and Reliable Performance
  • Standard dimensions to fit in commonly available housings
  • Lower consumption of chemical and longer life

Applications

  • Restaurants
  • Aquariums
  • Whole House (Residential)
  • Office
  • Institutions
  • Hotels
  • Hospitals
  • Spot Free Rinse/Car Wash
  • Labs
  • Pharmaceutical
  • Humidification
  • Misting
  • Manufacturing
  • Rinse Water
  • Bottled Water
  • Beverage
  • Food Processing
  • Ice Makers
  • Commercial Water Treatment
  • Wide Variety of Other Applications

Send your message to this supplier